-- AT-SYSINFO.MIB, Allied Telesis enterprise MIB:
-- Objects for system information
-- Copyright (c) 2006 by Allied Telesis, Inc.
-- All rights reserved.
--
-- ============================================================================

    AT-SYSINFO-MIB DEFINITIONS ::= BEGIN

        IMPORTS
            atRouter, DisplayStringUnsized
                FROM AT-SMI-MIB
            InterfaceIndex
                FROM IF-MIB
            OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
                FROM SNMPv2-SMI
            DisplayString
                FROM SNMPv2-TC;


        sysinfo MODULE-IDENTITY
            LAST-UPDATED "201009070000Z"
            ORGANIZATION
                "Allied Telesis, Inc."
            CONTACT-INFO
                "  http://www.alliedtelesis.com"
            DESCRIPTION
                "Subtree beneath which system inforamtion ids are assigned.
                It contains generic system information, as follows:
                { sysinfo 1 } fanAndPs
                { sysinfo 2 } restartGroup
                { sysinfo 3 } cpu
                { sysinfo 4 } sysTemperature
                { sysinfo 5 } atrContactDetails
                { sysinfo 6 } bbrNvs
                { sysinfo 9 } hostId
                { sysinfo 10 } envMon
                { sysinfo 11 } xem
                { sysinfo 12 } awpEnvMon
                { sysinfo 13 } awpStack
                { sysinfo 14 } atPortInfo"
            REVISION "200606140000Z"
            DESCRIPTION
                "Initial version of this MIB module."
            REVISION "200802260000Z"
            DESCRIPTION
                "Changed top DESCRIPTION section."
            REVISION "201006040000Z"
            DESCRIPTION
                "Added new object atPortRenumberEvents."
            REVISION "201006150015Z"
            DESCRIPTION
                "MIB revision history dates in descriptions updated."
            REVISION "201008160016Z"
            DESCRIPTION
                "Added SFP Plus descriptions to atPortInfoTransceiverEntry."
            REVISION "201008310031Z"
            DESCRIPTION
                "Added Infinband descriptions to atPortInfoTransceiverEntry."
            REVISION "201009070000Z"
            DESCRIPTION
                "Generic syntax tidy up"
            ::= { atRouter 3 }


--
-- Node definitions
--

--  fanAndPs traps - traps exist for changes to power supply status, fan status
--  and temperature status.

        fanAndPs OBJECT IDENTIFIER ::= { sysinfo 1 }


        fanAndPsTrap OBJECT IDENTIFIER ::= { fanAndPs 0 }


        fanAndPsRpsConnectionTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsRpsConnectionStatus }
            STATUS current
            DESCRIPTION
                "Generated when the RPS connection status changes."
            ::= { fanAndPsTrap 1 }


        fanAndPsMainPSUStatusTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsMainPSUStatus }
            STATUS current
            DESCRIPTION
                "Generated when the main power supply status changes."
            ::= { fanAndPsTrap 2 }


        fanAndPsRedundantPSUStatusTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsRedundantPSUStatus }
            STATUS current
            DESCRIPTION
                "Generated when the RPS status changes."
            ::= { fanAndPsTrap 3 }


        fanAndPsMainFanStatusTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsMainFanStatus }
            STATUS current
            DESCRIPTION
                "Generated when the main fan changes status."
            ::= { fanAndPsTrap 4 }


        fanAndPsRedundantFanStatusTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsRedundantFanStatus }
            STATUS current
            DESCRIPTION
                "Generated when the redundant fan changes status."
            ::= { fanAndPsTrap 5 }


        fanAndPsTemperatureStatusTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsTemperatureStatus }
            STATUS current
            DESCRIPTION
                "Generated when the temperature changes status."
            ::= { fanAndPsTrap 6 }


        fanAndPsFanTrayPresentTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsFanTrayPresent }
            STATUS current
            DESCRIPTION
                "Generated when the fan tray presence status changes."
            ::= { fanAndPsTrap 7 }


        fanAndPsFanTrayStatusTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsFanTrayStatus }
            STATUS current
            DESCRIPTION
                "Generated when the fan tray status changes."
            ::= { fanAndPsTrap 8 }


        fanAndPsMainMonitoringStatusTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsMainMonitoringStatus }
            STATUS current
            DESCRIPTION
                "Generated when the main power supply monitoring status changes."
            ::= { fanAndPsTrap 9 }


        fanAndPsAccelFanStatusTrap NOTIFICATION-TYPE
            OBJECTS { fanAndPsAccelFanStatus }
            STATUS current
            DESCRIPTION
                "Generated when the accelerator fans' status changes."
            ::= { fanAndPsTrap 10 }


        fanAndPsRpsConnectionStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                connected(1),
                notConnected(2),
                notMonitoring(3)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of the Redundant Power Supply (RPS) connection,
                ie, whether an RPS is actually connected or not, regardless
                of whether the RPS is on or not. notSupported means that an
                RPS is not supported in this hardware platform, connected
                means that the RPS is connected, notConnected means that the
                RPS is not connected, and notMonitoring means that the status
                of the RPS is not being monitored presently. RPS monitoring can
                be turned on via the variable fanAndPsRpsMonitoringStatus, or
                by the command SET SYSTEM RPSMONITOR=ON."
            ::= { fanAndPs 1 }


        fanAndPsMainPSUStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                on(1),
                off(2),
                faulty(3)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of the main Power Supply. on means that the power supply is present
                and fully operational. off means that the power supply is totally off (and
                obviously only applies to systems with a redundant power supply). faulty means
                that the main power supply is delivering power but that a component of the
                power supply is faulty. This applies to systems like SwitchBlade which have 3
                power supplies but do not provide individual power supply monitoring. Also,
                in the case of SwitchBlade, power supply status includes the status of the fans
                in the power supply."
            ::= { fanAndPs 2 }


        fanAndPsRedundantPSUStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                on(1),
                off(2),
                notMonitoring(3)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of the redundant Power Supply. notSupported means
                this device does not support redundant power supplies, on
                means that the redundant power supply is connected and able
                to supply system power if required, off means that the
                redundant power supply is either not connected or is connected
                and is not able to supply system power if required, and
                notMonitoring means that the status of the RPS is not being
                monitored presently. RPS monitoring can be turned on via the
                variable fanAndPsRpsMonitoringStatus, or by the command
                SET SYSTEM RPSMONITOR=ON."
            ::= { fanAndPs 3 }


        fanAndPsRpsMonitoringStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                on(1),
                off(2)
                }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The current status of redundant power supply monitoring. The
                monitoring of the redundant power supply and its fan must be
                enabled by command or by setting this variable to on. The value
                notSupported means that this device does not support redundant
                power supplies. Only the values on or off may be written to this
                variable. If this variables reads as notSupported, an attempt to
                write to this variable will result in a bad value error."
            ::= { fanAndPs 4 }


        fanAndPsMainFanStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                ok(1),
                notOk(2),
                warning(3)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of the main Power Supply fan. notSupported means that this
                device does not support monitoring on the main power supply fan, or that
                there is no main power supply fan. The warning means the fan's speed is
                outside 30% of the expected speed."
            ::= { fanAndPs 5 }


        fanAndPsRedundantFanStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                ok(1),
                notOk(2),
                notMonitoring(3)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of the redundant Power Supply Fan. notSupported means
                this device does not support redundant power supplies, ok
                means that the redundant power supply fan is running, notOk means
                that the redundant power supply fan is not running, and
                notMonitoring means that the status of the RPS is not being
                monitored presently. RPS monitoring can be turned on via the
                variable fanAndPsRpsMonitoringStatus, or by the command
                SET SYSTEM RPSMONITOR=ON."
            ::= { fanAndPs 6 }


        fanAndPsTemperatureStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                ok(1),
                notOk(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of temperature in this device. ok means that the
                device is not capable of monitoring temperature or that the
                temperature is OK, notOk means that the temperature is being
                monitored and is currently out of the range 0C - 45C."
            ::= { fanAndPs 7 }


        fanAndPsFanTrayPresent OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                present(1),
                notPresent(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of the presence of the fan tray in this system. Systems
                which do not support a fan tray return the value notSupported. Upon
                removal of the fan tray there is a short period (20s) before the value of
                this variable is changed to notPresent. This is to allow for scheduled
                replacement and/or cleaning of the fan tray."
            ::= { fanAndPs 8 }


        fanAndPsFanTrayStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                ok(1),
                notOk(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of the fan tray in this system. Systems which do not support
                a fan tray return the value notSupported. The value ok is returned if all fans
                in the fan tray are running at full speed. The value notOk is returned if
                one of more of the fan tray fans is running slow or has stalled."
            ::= { fanAndPs 9 }


        fanAndPsMainMonitoringStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                ok(1),
                notOk(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The current status of main power supply monitoring. The
                monitoring of the main power supply and its fan is always
                enabled by those systems that support it. Systems which do
                not support main power supply or fan monitoring report a
                value of notSupported. The value ok is returned for those
                systems that do support main power supply and fan monitoring,
                and where the monitoring operation is reporting valid information (refer
                to fanAndPsMainFanStatus for the current status of the system).
                When main power supply and fan monitoring is failing, the value
                notOk is returned."
            ::= { fanAndPs 10 }

--  fanAndPsPsuStatusTable - AT8948 specific power supply monitoring.

        fanAndPsPsuStatusTable OBJECT-TYPE
            SYNTAX SEQUENCE OF FanAndPsPsuStatusEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The table of AT8948 fanAndPsPsuStatusTable. Each entry in the table
                represents the status of one of the power supplies in AT8948 system.
                Each power supply has its own board ID."
            ::= { fanAndPs 11 }


        fanAndPsPsuStatusEntry OBJECT-TYPE
            SYNTAX FanAndPsPsuStatusEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "A single entry of AT8948 fanAndPsPsuStatusTable, indexed by
                fanAndPsPsuNumber field."
            INDEX { fanAndPsPsuNumber }
            ::= { fanAndPsPsuStatusTable 1 }


        FanAndPsPsuStatusEntry ::=
            SEQUENCE {
                fanAndPsPsuNumber
                    INTEGER,
                fanAndPsPsuPresent
                    INTEGER,
                fanAndPsPsuType
                    INTEGER,
                fanAndPsPsuFan
                    INTEGER,
                fanAndPsPsuTemperature
                    INTEGER,
                fanAndPsPsuPower
                    INTEGER
             }

        fanAndPsPsuNumber OBJECT-TYPE
            SYNTAX INTEGER (1..2147483647)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The PSU board identity for which this entry holds. If the system
                consists only of a single PSU board, only one entry will appear
                in the table, whose index is 1."
            ::= { fanAndPsPsuStatusEntry 1 }


        fanAndPsPsuPresent OBJECT-TYPE
            SYNTAX INTEGER
                {
                yes(0),
                no(1)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The PSU present state, displayed as 'yes' if present, or 'no' if absent."
            ::= { fanAndPsPsuStatusEntry 2 }


        fanAndPsPsuType OBJECT-TYPE
            SYNTAX INTEGER
                {
                ac(0),
                dc(1),
                fan(2),
                notPresent(3),
                notSupported(4)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The PSU type, displayed as AC, or DC, or FAN, or NOT PRESENT."
            ::= { fanAndPsPsuStatusEntry 3 }


        fanAndPsPsuFan OBJECT-TYPE
            SYNTAX INTEGER
                {
                ok(0),
                fail(1),
                notPresent(2),
                notSupported(3)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The PSU fan status, displayed as OK, or FAIL, or NOT PRESENT."
            ::= { fanAndPsPsuStatusEntry 4 }


        fanAndPsPsuTemperature OBJECT-TYPE
            SYNTAX INTEGER
                {
                good(0),
                high(1),
                notPresent(2),
                notSupported(3)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The PSU temperature, displayed as GOOD, or HIGH, or NOT PRESENT,
                or NOT SUPPORTED."
            ::= { fanAndPsPsuStatusEntry 5 }


        fanAndPsPsuPower OBJECT-TYPE
            SYNTAX INTEGER
                {
                good(0),
                bad(1),
                notPresent(2),
                notSupported(3)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The PSU power status, displayed as GOOD, or BAD, or NOT PRESENT
                or NOT SUPPORTED."
            ::= { fanAndPsPsuStatusEntry 6 }


        fanAndPsAccelFanStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                ok(1),
                notOk(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of the accelerator card fans. Non-supported means this
                device does not support monitoring of the accelerator card fans."
            ::= { fanAndPs 12 }


        restartGroup OBJECT IDENTIFIER ::= { sysinfo 2 }


        restart OBJECT-TYPE
            SYNTAX INTEGER
                {
                restartNone(0),
                restartWarm(1),
                restartCold(2)
                }
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "A router/switch restart request.

                A management station can remotely instruct an ATI router/switch
                to action a warm or cold restart.

                Once all the appropriate internal checks have been made, the
                router/switch will acknowledge the request via normal SNMP channels.
                The restart instruction will be actioned after waiting for a period
                of 5 seconds, this is because the SNMP acknowledgement packet needs
                time to reach the management station.

                Once the request has been actioned, it can not be cancelled and
                communication with the router/switch will be lost during system
                initialisation."
            ::= { restartGroup 1 }


        restartCause OBJECT-TYPE
            SYNTAX INTEGER
                {
                unknown(0),
                hardwareReset(1),
                hardwareWatchdog(2),
                softwareRequest(3),
                softwareException(4),
                softwareInvalidImage(5),
                softwareLicenceCheckFailure(6),
                powerOnSelfTestfailure(7)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The reason for last time restart."
            ::= { restartGroup 2 }


        restartLog OBJECT-TYPE
            SYNTAX DisplayStringUnsized (SIZE (0..500))
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The restart logging details."
            ::= { restartGroup 3 }


        restartNotification NOTIFICATION-TYPE
            OBJECTS { restartCause }
            STATUS current
            DESCRIPTION
                "A restart notification is a trap sent to tell snmp managers
                the reason of restarting"
            ::= { restartGroup 11 }


--  cpu - this group contains information about the cpu utilisation over different
--  periods of time.
        cpu OBJECT IDENTIFIER ::= { sysinfo 3 }


        cpuUtilisationMax OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Maximum CPU utilisation since the router was last restarted.
                Expressed as a percentage."
            ::= { cpu 1 }


        cpuUtilisationAvg OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Average CPU utilisation since the router was last restarted.
                Expressed as a percentage."
            ::= { cpu 2 }


        cpuUtilisationAvgLastMinute OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Average CPU utilisation over the past minute.
                Expressed as a percentage."
            ::= { cpu 3 }


        cpuUtilisationAvgLast10Seconds OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Average CPU utilisation over the past ten seconds.
                Expressed as a percentage."
            ::= { cpu 4 }


        cpuUtilisationAvgLastSecond OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Average CPU utilisation over the past second.
                Expressed as a percentage."
            ::= { cpu 5 }


        cpuUtilisationMaxLast5Minutes OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Maximum CPU utilisation over the last 5 minutes.
                Expressed as a percentage."
            ::= { cpu 6 }


        cpuUtilisationAvgLast5Minutes OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Average CPU utilisation over the past 5 minutes.
                Expressed as a percentage."
            ::= { cpu 7 }

--  sysTemperature - this group contains information about the temperature monitoring
--  in the system. under this group is a general group, containing generic temperature
--  monitoring variables, and one or more specific groups, which contain variables specific
--  to particular products.

        sysTemperature OBJECT IDENTIFIER ::= { sysinfo 4 }

--  This group displays generic system temperature information - the actual
--  temperature, the  fixed temperature threshold and an indication the
--  temperature has fallen below the threshold. A particular product may support
--  this information or not. If not the product may have a specific entry for
--  its particular temperature information. A product may also support the
--  generic information and additional specific information.

        generalTemperature OBJECT IDENTIFIER ::= { sysTemperature 1 }


        generalTemperatureTrap OBJECT IDENTIFIER ::= { generalTemperature 0 }

--  generalTemperature trap - a trap monitoring changes in the temperature status.

        generalTemperatureStatusTrap NOTIFICATION-TYPE
            OBJECTS { generalTemperatureStatus, generalTemperatureActualTemp, generalTemperatureThreshold }
            STATUS current
            DESCRIPTION
                "Generated when the temperature status of the device changes."
            ::= { generalTemperatureTrap 1 }


        generalTemperatureSupported OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                supported(1)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The value supported indicates general temperature is displayed by the
                device. The value notSupported indicates the device displays specific
                temperature information or none at all."
            ::= { generalTemperature 1 }


        generalTemperatureActualTemp OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The current temperature of product's base board, in degrees Celsius. A device
                which doesn't support this group will return the value 0 for this variable."
            ::= { generalTemperature 2 }


        generalTemperatureStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                ok(1),
                notOk(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of temperature in this device. ok indicates the
                temperature is below the threshold temperature or the device
                is not capable of monitoring temperature. notOk indicates the
                temperature is being monitored and is currently above the
                threshold temperature (displayed in generalTemperatureThreshold)."
            ::= { generalTemperature 3 }


        generalTemperatureThreshold OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The temperature threshold for the device. If the
                temperature of the device rises above this threshold
                generalTemeratureStatus will indicate a notOk status."
            ::= { generalTemperature 4 }


--  sbTemperature - SwitchBlade specific temperature monitoring.

        sbTemperature OBJECT IDENTIFIER ::= { sysTemperature 2 }


        sbTemperatureTrap OBJECT IDENTIFIER ::= { sbTemperature 0 }


        sbTempFixedThresholdTrap NOTIFICATION-TYPE
            OBJECTS { sbTempFixedThresholdStatus, sbTempActualTemperature, sbTempFixedThreshold }
            STATUS current
            DESCRIPTION
                "Trap occurs when fixed threshold status changes. The actual temperature
                and the fixed threshold are also given."
            ::= { sbTemperatureTrap 1 }


        sbTempSettableThresholdTrap NOTIFICATION-TYPE
            OBJECTS { sbTempSettableThresholdStatus, sbTempActualTemperature, sbTempSettableThreshold }
            STATUS current
            DESCRIPTION
                "Trap occurs when settable threshold status changes. The actual temperature
                and the settable threshold are also given."
            ::= { sbTemperatureTrap 2 }


        sbTempTable OBJECT-TYPE
            SYNTAX SEQUENCE OF SbTempEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The table of SwitchBlade sysTemperature. Each entry in the table
                represents temperature monitoring from one of the CPU cards which
                may be present in the SwitchBlade system."
            ::= { sbTemperature 1 }


        sbTempEntry OBJECT-TYPE
            SYNTAX SbTempEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "A single entry of SwitchBlade sysTemperature"
            INDEX { sbTempIndex }
            ::= { sbTempTable 1 }


        SbTempEntry ::=
            SEQUENCE {
                sbTempIndex
                    INTEGER,
                sbTempActualTemperature
                    INTEGER,
                sbTempFixedThresholdStatus
                    INTEGER,
                sbTempSettableThresholdStatus
                    INTEGER,
                sbTempSettableThreshold
                    INTEGER
             }

        sbTempIndex OBJECT-TYPE
            SYNTAX INTEGER
                {
                master(1),
                slave(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The board for which this temperature entry holds. If the system
                consists only of a single CPU board, only one entry will appear
                in the table, whose index is master(1)."
            ::= { sbTempEntry 1 }


        sbTempActualTemperature OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The actual SwitchBlade temperature. This temperature is measured
                within the SwitchBlade CPU, and is sampled at 1 second intervals."
            ::= { sbTempEntry 2 }


        sbTempFixedThresholdStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                normal(1),
                crossover(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The temperature status with regard to the fixed temperature
                threshold. The value of the fixed temperature threshold is set at
                90 degrees C. This variable represents whether the actual temperature
                is above the threshold (value is crossover(2)) or below the threshold
                (value is normal(1)). If the temperature is exactly the same as the
                fixed temperature threshold, the value of this variable reads as
                normal(1)."
            ::= { sbTempEntry 3 }


        sbTempSettableThresholdStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                normal(1),
                crossover(2),
                undefined(3)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The temperature status with regard to the settable temperature
                threshold. The value of the settable temperature threshold is set by
                management intervention. This variable represents whether the actual
                temperature is above the threshold (value is crossover(2)) or below
                the threshold (value is normal(1)). When the value of this variable is
                undefined(3), no settable threshold has been specified and the value
                of sbTempSettableThreshold is not used."
            ::= { sbTempEntry 4 }


        sbTempSettableThreshold OBJECT-TYPE
            SYNTAX INTEGER (30..100)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The value of the settable temperature threshold. This can be set
                independently for each temperature entry. The value of this threshold
                is only valid when sbTempSettableThresholdStatus is not set to
                undefined(3)."
            ::= { sbTempEntry 5 }


        sbTempFixedThreshold OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The value of the fixed temperature threshold. This value is fixed for
                both CPU cards, and cannot be set."
            ::= { sbTemperature 2 }


--  acceleratorTemperature - Accelerator card specific temperature monitoring.

        acceleratorTemperature OBJECT IDENTIFIER ::= { sysTemperature 3 }


        acceleratorTemperatureTrap OBJECT IDENTIFIER ::= { acceleratorTemperature 0 }


        acceleratorTemperatureStatusTrap NOTIFICATION-TYPE
            OBJECTS { acceleratorTemperatureStatus }
            STATUS current
            DESCRIPTION
                "Generated when the temperature status of the device changes."
            ::= { acceleratorTemperatureTrap 1 }


        acceleratorTemperatureSupported OBJECT-TYPE
            SYNTAX INTEGER
                {
                notSupported(0),
                supported(1)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The value supported indicates whether accelerator card temperature
                is displayed by the device. The value notSupported indicates the
                device does not display specific accelerator card temperature
                information."
            ::= { acceleratorTemperature 1 }


        acceleratorTemperatureActualTemp OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The current temperature of product's base board, in degrees Celsius. A device
                which doesn't support this group will return the value 0 for this variable."
            ::= { acceleratorTemperature 2 }


        acceleratorTemperatureStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                ok(1),
                notOk(2)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The status of temperature in this device. ok indicates the
                temperature is below the threshold temperature or the device
                is not capable of monitoring temperature. notOk indicates the
                temperature is being monitored and is currently above the
                threshold temperature (displayed in generalTemperatureThreshold)."
            ::= { acceleratorTemperature 3 }


        acceleratorTemperatureThreshold OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The temperature threshold for the device. If the
                temperature of the device rises above this threshold
                generalTemeratureStatus will indicate a notOk status."
            ::= { acceleratorTemperature 4 }

--  acceleratorTemperature trap - a trap monitoring changes in the temperature status.

        atContactDetails OBJECT-TYPE
            SYNTAX DisplayString
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The contact details for Allied Telesis inc."
            ::= { sysinfo 5 }

--  bbrNvs - this group contains information about the battery backed RAM non-volatile storage
--  in the router.

        bbrNvs OBJECT IDENTIFIER ::= { sysinfo 6 }


        bbrNvsTrap OBJECT IDENTIFIER ::= { bbrNvs 0 }


        bbrNvsReinitialiseTrap NOTIFICATION-TYPE
            STATUS current
            DESCRIPTION
                "Generated at boot when the device detects that the BBR has been
                corrupted and reinitialised. This can happen if the device's BBR
                battery has run down, and the device has been powered off, then on."
            ::= { bbrNvsTrap 1 }


--  memory - this group contains information about the current memory status
--  of the router.
        memory OBJECT IDENTIFIER ::= { sysinfo 7 }


        freeMemory OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Percentage of free memory still available on device"
            ::= { memory 1 }


        totalBuffers OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Total number of buffers available on device"
            ::= { memory 2 }


        lowMemoryTrap NOTIFICATION-TYPE
            OBJECTS { freeMemory, totalBuffers }
            STATUS current
            DESCRIPTION
                "A low memory trap is generated when a router's memory
                has gone below a certain level."
            ::= { memory 11 }


        realTimeClockStatus OBJECT-TYPE
            SYNTAX INTEGER
                {
                invalid(0),
                normal(1)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "Shows the status of the real time clock"
            ::= { sysinfo 8 }


        hostId OBJECT-TYPE
            SYNTAX INTEGER (0..32)
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "Host Identifier of this device"
            ::= { sysinfo 9 }


        atPortInfo OBJECT IDENTIFIER ::= { sysinfo 14 }


        atPortInfoTransceiverTable OBJECT-TYPE
            SYNTAX SEQUENCE OF AtPortInfoTransceiverEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "A table of information about the transceiver of a interface."
            ::= { atPortInfo 1 }


        atPortInfoTransceiverEntry OBJECT-TYPE
            SYNTAX AtPortInfoTransceiverEntry
            MAX-ACCESS not-accessible
            STATUS current
            DESCRIPTION
                "The description, the transceiver type of a interface."
            INDEX { atPortInfoTransceiverifIndex }
            ::= { atPortInfoTransceiverTable 1 }


        AtPortInfoTransceiverEntry ::=
            SEQUENCE {
                atPortInfoTransceiverifIndex
                    InterfaceIndex,
                atPortInfoTransceiverType
                    INTEGER
             }

        atPortInfoTransceiverifIndex OBJECT-TYPE
            SYNTAX InterfaceIndex
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The ifIndex for the interface represented
                by this entry of the interfaces table."
            ::= { atPortInfoTransceiverEntry 1 }


        atPortInfoTransceiverType OBJECT-TYPE
            SYNTAX INTEGER
                {
                rj45(1),
                sfp-px(2),
                sfp-bx10(3),
                sfp-fx(4),
                sfp-100base-lx(5),
                sfp-t(6),
                sfp-cx(7),
                sfp-zx-cwdm(8),
                sfp-lx(9),
                sfp-sx(10),
                sfp-oc3-lr(11),
                sfp-oc3-ir(12),
                sfp-oc3-mm(13),
                xfp-srsw(14),
                xfp-lrlw(15),
                xfp-erew(16),
                xfp-sr(17),
                xfp-lr(18),
                xfp-er(19),
                xfp-lrm(20),
                xfp-sw(21),
                xfp-lw(22),
                xfp-ew(23),
                unknown(24),
                empty(25),
                sfpp-sr(26),
                sfpp-lr(27),
                sfpp-er(28),
                sfpp-lrm(29),
                inf-1-x-copper-pasv(30),
                inf-1-x-copper-actv(31),
                inf-1-x-lx(32),
                inf-1-x-sx(33)
                }
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "This object indicates the type of transceiver on a interface."
            ::= { atPortInfoTransceiverEntry 2 }


        atPortRenumberEvents OBJECT-TYPE
            SYNTAX INTEGER
            MAX-ACCESS read-only
            STATUS current
            DESCRIPTION
                "The number of times that port number values (represented by the
                dot1dBasePort object in BRIDGE-MIB), have been re-assigned due to
                stack member leave/join events or XEM hot-swap events, since the
                system was initialised."
            ::= { atPortInfo 2 }



    END

--